Mass flow rate, volumetric flow s. c. (standard condition), volumetric flow a. c. (actual condition), molecular weight, gas volume and mass, gas velocity, sound velocity
Mass flow rate, volumetric flow s. c. (standard condition), volumetric flow a. c. (actual condition), molecular weight, gas volume and mass, gas velocity, sound velocity
Measuring range
0,03 m/s ... 120 m/s (0.1 ft/s ... 394 ft/s)
Max. Measurement error
Volumetric flow, a. c.; 1 % ... 5 % Related to the measured value with ultrasonic technology (in the range ≥ 0.3 m/s (≥ 1 ft/s) to measuring range end value) 0,5 % ... 1,5 % with spool piece and flow calibration Related to the measured value with ultrasonic technology (in the range ≥ 1.0 m/s (≥ 3.3 ft/s) to calibration range end value
Mass flow rate a.c.; 2 % ... 5.5 % Related to the measured value with ultrasonic technology (in the range ≥ 0.3 m/s (≥ 1 ft/s) to measuring range end value) 1,5 % ... 2 % with spool piece and flow calibration Related to the measured value with ultrasonic technology (in the range ≥ 1 m/s (≥ 3.3 ft/s) to calibration range end value)
Interface Unit IECEx: Zone 1: Ex db eb ia IIC T4 Gb Zone 1: Ex db ia IIC T4 Gb Zone 2: EX ec ia IIC T4 Gc
ATEX: Zone 1: II 2G Ex db eb ia IIC T4 Gb Zone 1: II 2G Ex db ia IIC T4 Gb Zone 2: II 3G Ex ec ia IIC T4 Gc
NEC/CEC (US/CA): Class I, Zone 1, AEx d ia IIC T4 Gb Class I, Division 1, Groups B, C, D, T4 Class I, Zone 2, AEx ec ia IIC T4 Gc Class I, Division 2, Group A, B, C and D, T4
Sensors F1F-S/P/R: IECEx: Zone 1: Ex db [ia Ga] IIC T6 Ga/Gb ATEX: Zone 1: II 1/2 G Ex db [ia Ga] IIC T6 Ga/Gb NEC/CEC (US/CA): Class I, Division 1, Groups B, C and D, T4; Class I, Zone 1, Ex/AEx d[ia] IIB + H2, T4;
F1F-M: IECEx: Zone 1: Ex db [ia Ga] IIB T4 Ga/Gb ATEX: Zone 1: II 1/2 G Ex db [ia Ga] IIB T4 Ga/Gb NEC/CEC (US/CA): Class I, Division 1, Groups C and D, T4; Class I, Zone 1, Ex/AEx d[ia] IIB, T4;
F1F-H: IECEx: Zone 1: Ex db IIC T6 Gb ATEX: Zone 1: II 2 G Ex db IIC T6 Gb NEC/CEC (US/CA): Class I, Division 1, Groups B, C and D, T4; Class I, Zone 1, Ex/AEx d IIB + H2, T4;
Outputs
Up to 6 outputs when using I/O modules (Option) 16 bit: 4 ... 20 mA 7 V DC ... 30 V DC In accordance with NAMUR NE43 Passive, galvanically isolated Reverse polarity protection
Digital Outputs
Switching output: Up to 6 outputs when using I/O module (option) Electrically isolated Max. current: 70 mA Max. switching frequency: 50 Hz Max. input voltage: 30 V DC Max. saturation voltage at output: 0.5 V DC Switchable Namur/open collector Reverse polarity protection
Digital output/Frequency output: Up to 12 digital outputs when using I/O modules (option) Electrically isolated Max. current: 50 mA Max. switching frequency: 10 kHz Max. input voltage: 30 V DC Max. saturation voltage at output: 1.8 V DC Switchable Namur/open collector Reverse polarity protection
FLOWSIC100 Flare-XT – Gas flow measuring instruments
英语版 - 01/2025
New version available in English
The gas flow measuring device FLOWSIC100 Flare-XT features a unique flow-optimized sensor design, which allows reliable
measurements at high gas velocities and changing gas compositions.
Oil and gas – solutions for the oil and gas industry
工业解决方案(SO)
英语版 - 01/2025
New version available in English
Endress+Hauser offers the best solutions through a huge range of products and systems to measure and perform even under the most rigorous operating conditions.
FLOWSIC100 Flare-XT – Gas flow measuring instruments
创新(IN)
英语版 - 01/2025
New version available in English
The gas flow measuring device FLOWSIC100 Flare-XT features a unique flow-optimized sensor design, which allows reliable measurements at high gas velocities and changing gas compositions.