Fieldgate FXA42 is developed for monitoring of field devices with digital or 4 to 20mA interface regardless of location. It supports communication interfaces like Ethernet, WLAN or cellular communication. With its integrated web server technology it can easily be configured online and measured values can be visualized online. FXA42 also offers data logging and alarm management functions.
For remote monitoring of connected 4 to 20mA analog as well as digital field devices via Ethernet, WLAN or cellular communication.
Measured values can be viewed with a standard internet browser
Configuration of measuring and transmission cycles
Configurable monitoring of limit values with alarm signaling via email or text
Four 4 to 20mA inputs, 4 digital input and output channels
Modbus TCP and Modbus RTU
Lợi ích
Level, flow and pressure visualization at the desk regardless of location
Simple configuration of Fieldgate and easy visualization of measured values via its integrated web server
Connects to SupplyCare Enterprise and SupplyCare Hosting
Advanced functions and actions from logic programming
Limit value monitoring with alarm via email or SMS
Tank monitoring with limit status from the analog inputs (HH, H, L, LL)
Easy connection to field devices and connectivity to 3rd party systems
Ethernet/analog or binary signal Gateway for SupplyCare with integrated Web server
Input
4x 4...20 mA analog 4x digital Pulse counter Modbus TCP Modbus RS485
Output
4x digital Modbus TCP Modbus RS485
Relay output signal type
None
Memory
SD Card 1GB
Power supply
24V DC
Dimensions (WxHxD)
45 mm x 100 mm x 115 mm (1.77" x 3.93" x 4.53")
Communication interface
Ethernet WLAN Cellular
System requirements
Mozilla Firefox Version 31 or newer Google Chrome Version 31 or newer Microsoft Edge Internet Explorer 10 or newer For mobile devices: iOS Safari 7.1 or newer Android Firefox or Chrome from Version 31
How may the operator optimize the chemical injection process and minimize Health, Safety and Environment (HSE) risks? This White Paper answers exactly this. It is about integrating the best fitting level mearurement instrumentation and a suitab le Inventory Management System.
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Chúng tôi sử dụng cookie để nâng cao trải nghiệm duyệt web của bạn, thu thập số liệu thống kê để tối ưu hóa chức năng của trang web và cung cấp nội dung hoặc quảng cáo phù hợp.
Bằng cách chọn "Chấp nhận tất cả", bạn đồng ý với việc sử dụng cookie của chúng tôi.
Để biết thêm chi tiết, vui lòng xem lại Chính sách cookie của chúng tôi.