Raman spectroscopy - advanced optical analysis technology
Boost plant safety, ensure product quality, and optimize operations. Raman spectroscopy measures the composition and molecular structure of your samples from lab-to-process in real time.
Raman Rxn-10 probe
Metal: C276 alloy as standard (316L stainless steel or Grade 2 titanium upon request)
Window: high-purity sapphire, proprietary compression fit non-brazed design
The fixed focus design of the Raman immersion optic provides long-term measurement stability along with superior signal performance which is essential for transferable, high-performance Raman measurements. Compatible with the Rxn-10 probe, the immersion optic uses no movable parts so it is always in focus. The Raman immersion optic is well-suited for use in reaction vessels, laboratory reactors, or process streams, and its wettable components resist corrosion in harsh environments.
Pharmaceutical: drug substance unit operations, reaction analysis, crystallization, end-point detection, solvent swaps
Chemical: material identification, reaction analysis, polymerization, cross-linking, blending
Food & Beverage: blending, purification, natural and synthetic components
Development laboratory: versatile in situ analysis, feasibility studies, model development (or similar)
Ideal for quick measurements of liquids, slurries, and semi-solids in a laboratory setting
Superior signal performance
Available in 1/4” and 1/2” diameters
No user-adjustable parts
Wettable components resist corrosion in harsh environments (including acidic solutions)
Sản phẩm cao cấp
Công nghệ vượt trội
Đơn giản
Sản phẩm chuyên dụng
Công nghệ vượt trội
Đơn giản
Có thể thay đổi
Lựa chọn FLEX | Công nghệ vượt trội | Đơn giản |
---|---|---|
Lựa chọn Fundamental Đáp ứng nhu cầu đo lường cơ bản |
Công nghệ vượt trội
|
Đơn giản
|
Lựa chọn Lean Xử lý dễ dàng các quy trình cốt lõi |
Công nghệ vượt trội
|
Đơn giản
|
Lựa chọn Extended Tối ưu hóa quy trình bằng công nghệ tiên tiến |
Công nghệ vượt trội
|
Đơn giản
|
Lựa chọn Xpert Làm chủ các ứng dụng khó khăn nhất |
Công nghệ vượt trội
|
Đơn giản
Có thể thay đổi |
System design and specifications for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL),
and Raman optic system for single use (KRSU1)
EN | VI | ||
31/05/2023
|
|
|
|
03/08/2022
|
|
|
Ngôn ngữ: |
Tiếng Anh |
Phiên bản: |
31/05/2023 |
Cỡ tập tin: |
467.9 KB |
Tên tập tin: |
TI01635CEN_0322.pdf |
System design and specifications
for the Raman Rxn-10 probe
EN | VI | ||
31/05/2023
|
|
|
Ngôn ngữ: |
Tiếng Anh |
Phiên bản: |
31/05/2023 |
Cỡ tập tin: |
423 KB |
Tên tập tin: |
TI01629CEN_0322.pdf |
Commissioning, operation, and maintenance details
for Rxn-10 probe optics: Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL)
and Raman optic system for single use (KRSU1)
EN | VI | ||
31/05/2023
|
|
|
|
03/08/2022
|
|
|
Ngôn ngữ: |
Tiếng Anh |
Phiên bản: |
31/05/2023 |
Cỡ tập tin: |
1.8 MB |
Tên tập tin: |
BA02171CEN_0322.pdf |
Commissioning, operation, and maintenance details
for the Raman Rxn-10 probe
EN | VI | ||
31/05/2023
|
|
|
Ngôn ngữ: |
Tiếng Anh |
Phiên bản: |
31/05/2023 |
Cỡ tập tin: |
1.2 MB |
Tên tập tin: |
BA02160CEN_0322.pdf |
Quick start guide for the Raman Rxn-10 probe
Ngôn ngữ: |
Tiếng Anh |
Phiên bản: |
31/05/2023 |
Cỡ tập tin: |
895.3 KB |
Tên tập tin: |
KA01546CEN_0322.pdf |
Quickstart guide for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL),
and Raman optic system for single use (KRSU1)
EN | VI | ||
31/05/2023
|
|
|
|
03/08/2022
|
|
|
Ngôn ngữ: |
Tiếng Anh |
Phiên bản: |
31/05/2023 |
Cỡ tập tin: |
1 MB |
Tên tập tin: |
KA01551CEN_0322.pdf |
ライフサイエンス産業向けラマン分光法アプリケーションノート(
ラマンRxn2アナライザー、ラマンRxn4アナライザー、Rxn-10プロー
ブ、Rxn-20プローブ、Rxn-45プローブ、Rxn-46プローブ、プローブ
オプティックアクセサリ(bIOオプティック、シングルユース向け
ラマンオプティックシステム/SUB、浸漬オプティック、非接触オプ
ティック)。
Ngôn ngữ: |
Tiếng Nhật |
Phiên bản: |
02/08/2024 |
Cỡ tập tin: |
1.4 MB |
Tên tập tin: |
PU01447CJA_0222_Raman_App_Guide_for_LifeScience.pdf |
A guide to our Raman spectroscopy application notes for the
Life Science industry (featuring the Raman Rxn2 analyzer,
Raman Rxn4 analyzer, Rxn-10 probe, Rxn-20 probe, Rxn-45 probe,
Rxn-46 probe, and probe accessory optics (bIO-Optic, Raman single
use optic system / SUB, immersion optic, non-contact optic).
Ngôn ngữ: |
Tiếng Anh |
Phiên bản: |
19/04/2022 |
Cỡ tập tin: |
1.1 MB |
Tên tập tin: |
PU01447CEN_0222.pdf |
A guide to Raman spectroscopy application notes for the
food & beverage industry (featuring studies using the
Raman Rxn2 analyzer, Raman Rxn4 analyzer, Rxn-10 probe,
Rxn-20 probe, Rxn-45 probe, and the immersion optic
and non-contact optic).
Ngôn ngữ: |
Tiếng Anh |
Phiên bản: |
17/02/2022 |
Cỡ tập tin: |
859 KB |
Tên tập tin: |
CP01489CEN_0122.pdf |
An overview brochure about our Raman spectroscopy probe
portfolio including the Rxn-10 probe, Rxn-20 probe, Rxn-30 probe,
Rxn-40 probe, Rxn-41 probe, Rxn-45 probe, Rxn-46 probe, and
probe accessory optics (bIO-Optic, Raman single use optic system /
SUB, immersion optic , non-contact optic), powered by Kaiser Raman
technology.
Ngôn ngữ: |
Tiếng Anh |
Phiên bản: |
26/10/2021 |
Cỡ tập tin: |
4.9 MB |
Tên tập tin: |
IN01225CEN_0121.pdf |