Measuring range
Trace: 0 to 5 mg/l ClO2
Standard: 0 to 20 mg/l ClO2
High: 0 to 200 mg/l ClO2 -
Process temperature
0 to 55 °C , non-freezing
(32 to 130 °F) -
Process pressure
Max. 2 bar abs
(Max. 29 psi abs)
Field of application
Memosens CCS50D is a robust, low maintenance sensor for chlorine dioxide measurement. It provides stable and fast measured values in drinking water, process water and utilities. The sensor can be used to ensure efficient disinfection for highest water quality and safety, to avoid overdosing of chlorine dioxide or to ensure the absence of ClO2 in beverage plants and reverse osmosis. Memosens CCS50D is not the latest Memosens generation. More information on the new Memosens CCS50E sensor here.
Memosens CCS50D is a chlorine dioxide sensor for skid builders and end customers. It measures reliably in:
Drinking water to ensure sufficient disinfection
Cooling systems or towers to avoid pathogen growth
Process water - for hygienic and safe packaging and bottling of products
Beverage plants to secure the absence of chlorine dioxide
Benefits
The right sensor version for every application: From trace measurement up to chlorine dioxide concentrations of 200 mg/l.
Fast response time provides accurate process view and enables prompt reaction to process changes as well as efficient process control.
Increased process safety: precise and long-term stable measurement ensures consistent process monitoring and allows for lowest disinfectant concentration.
-
Flexible installation: sensor can be installed in the CCA151 and CCA250 flow assemblies or in immersion assemblies. Measurement virtually flow independent at flow velocities above 5 l/h (CCA151), 30 l/h (CCA250) or above 15 cm/s (immersion).
More process up-time thanks to fast sensor exchange: precalibrate the sensor in your lab and then swap it into your process with plug & play.
Connection to the Liquiline multiparameter transmitter allows easy combination with other relevant parameters of liquid analysis.
Extended selection
-
High-end products
- Highly functional and convenient
Technical excellence
Simplicity
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
-
Technical Information (TI)
Memosens CCS50D Technical Information
Digital sensor with Memosens technology for determining chlorine dioxide
EN 08/02/201919/05/2017Language:
English
Version:
08/02/2019
File size:
724 KB
File name:
TI01353CEN_0219.pdf
-
-
-
Operating Instruction (BA)
CCS50D
Digital sensor with Memosens technology for determining chlorine dioxide
EN 20/07/202008/02/201919/05/2017Language:
English
Version:
20/07/2020
File size:
1.4 MB
File name:
BA01773CEN_0320.pdf
-
-
-
PU (Publication)
Disinfection applications
Measuring ranges and suitable sensors
Language:
English
Version:
16/06/2023
File size:
603.1 KB
File name:
PU01405CEN-disinfection-sensor-application.pdf
-
-
-
PU (Publication)
Energy savings in utilities: Solutions for steam, compressed air, heating, cooling and industrial gases
Solutions for steam, compressed air,
heating, cooling and industrial gasesLanguage:
English
Version:
07/12/2023
File size:
9.8 MB
File name:
PU01539Z24EN012300_US VersionEnergy_savings_Utilities_eBook.pdf
-
-
-
PU (Publication)
Úspory energie v technologických zařízeních
Řešení pro páru,
stlačený vzduch,
vytápění, chlazení
a průmyslové plynyLanguage:
Czech
Version:
14/03/2024
File size:
26.8 MB
File name:
PU01539ZCS0124_Energy_savings_Utilities_eBook.pdf
-
-
-
PU (Publication)
Desinfektionsanwendungen
Messbereiche und geeignete
SensorenLanguage:
German
Version:
03/11/2023
File size:
678.7 KB
File name:
PU01405CDE_02.23_Desinfektionsanwendungen.pdf
-
-
-
PU (Publication)
Ahorro energético en servicios generales: Soluciones para vapor, aire comprimido, calefacción, refrigeración y gases industriales
Soluciones para vapor, aire comprimido,
calefacción, refrigeración y gases industrialesLanguage:
Spanish
Version:
30/04/2024
File size:
10.2 MB
File name:
ES_PU01539Z_0123_Energy_savings_Utilities_eBook_Global.pdf
-
-
-
PU (Publication)
Решения для систем, работающих с паром
Решения для систем, работающих с паром
Language:
Russian
Version:
25/04/2024
File size:
10.4 MB
File name:
PU01539Z_0123_Energy_savings_Utilities_eBook_Global-ru.pdf
-
-
-
PU (Publication)
Energieeinsparungen in Hilfskreislaeufen
Energiesparloesungen für Dampf, Druckluft,
Heizung, Kühlung und IndustriegasLanguage:
German
Version:
06/10/2023
File size:
3.1 MB
File name:
PU01539Z11DE0123_Energieeinsparungen_eBook.pdf
-
-
-
PU (Publication)
E-book Energiebesparingen in utiliteiten
Oplossingen voor stoom, perslucht,
verwarming, koeling en industriële gassenLanguage:
Dutch
Version:
27/03/2024
File size:
8.5 MB
File name:
PU01539Z15NL0124_eBook Energiebesparingen in utiliteiten.pdf
-